Procedure
Overview
The Alarm.com Flex IO® sensor enables new levels of flexibility for monitoring valuable property and assets anywhere that LTE connectivity is available. Whether used with a backyard gate or a remote storage unit, the Alarm.com Flex IO® sensor empowers users to keep an eye on what matters most. It can be used with the included magnet to monitor doors, gates, and other entryways. It also comes equipped with input and output options for integrating compatible devices that lack long-range connectivity.
Features
Detect open/close using magnetic reed switch
Detect state change for third-party device using Loop Input
Change state of third-party and device using Relay Output (requires DC power to support always-on cellular connection)
For more information about supported use cases, see Alarm.com Flex IO® sensor - Supported Use Cases.
In the box
Optional EOL (end of line) resistor to detect cut wires. EOL resistor can be 300 kΩ or higher. Normally Open configuration is preferred for low power usage.
Optional mount tamper and battery door tamper alerts
Multiple mounting options, including screws or zip ties.
Multiple carrier options
Verizon (US only)
AT&T (US and Canada)
Specifications
Ingress Protection
IP56
Temperature
Battery life will be optimal between temperatures of 32°F to 131°F (0°C to 55°C), though the device can operate from -40°F to 131°F (-40°C to 55°C).
Reed Switches
3 unique reed switch locations to choose from that can be activated with included magnet.
Loop Input
The Alarm.com Flex IO® sensor can be powered by battery or external power.
Dry Contact, Normally Open (NO), or Normally Closed (NC).
Optional EOL resistor can be 300 kΩ or higher.
Relay Output
If used, the Alarm.com Flex IO® sensor must be externally powered (not compatible with battery power).
Up to 24 V (AC or DC), 40 mA max current.
Can be used only for control lines/dry contact.
Caution: Can never be connected directly to control electrical loads. This will damage the device.
Dimensions
Main unit: 6.8 x 2.2 x 1.3" (17.3 x 5.6 x 3.3 cm).
Magnet: 3.1 x 0.68 x 0.87" (7.9 x 1.7 x 2.2 cm).
- Power
Works with DC-wired power or battery power (battery backup recommended for wired installations).
Supply Voltage: 6 to 15 VDC
Device Max Current Draw: 500 mA
Max Power Consumption: Up to 7.5 W (at 15 VDC)
Battery Power
Four 1.5 V AA lithium batteries (iron disulfide).
2+ years of battery life, depending on battery chemistry and operating temperature.
Maximum Installation Height
2000 meters above ground level
Source and support
For GoSafer Security assistance, visit gosafersecurity.com.
Original Alarm.com reference: https://answers.alarm.com/Customer/Website_and_App/Cellular_Sensor/Alarm.com_Flex_IO_sensor/Alarm.com_Flex_IO_sensor_-_Data_Sheet
Always verify safety, installation, compatibility, and current UI details against the original manufacturer documentation before operational use.
No comments to display
No comments to display